owners manual
10
Quantum II
note
system operation
•On Quantum II set Ch A & B volume controls to
off (counter clock wise)
•Turn the Quantum II “ON”, Blue LED will light
•Confirm power to ceiling sensor, Green LED on
edge of sensor will light
•Using a Sapphire Transmitter microphone.
(Sapphire Mics are shipped in channel A)
Sapphire: “AB” switch, remove battery cover
on back, under battery.
Handheld: Unscrew barrel and remove.
Note “AB” switch on side of battery holder.
•Turn sensitivity control on Sapphire transmitter
to "HI" level position
•Switch transmitter “on” by depressing and hold
front button until (Blue) LED is present
•Observe signal presence LED (Orange) on
Quantum II receiver adjacent to “Mic” volume
control
•Stand under or in front of a speaker
•Slowly adjust “Ch A” volume on Quantum II
while talking into microphone
•Adjust to desired listening level.
CAUTION: Beware of feedback
•Walk around the room while talking into
microphone to confirm good connectivity
Upon completion of performance test,
the installation is complete.
Now that the system is installed and connected, we are ready to turn the system “ON” and test
its performance. The testing will be done using an IR transmitter (Sapphire or Handheld) to
confirm good connectivity and quality audio.
operation of wireless microphone